Personal Information
Stephen J. Dodd Staff Scientist NIH, NINDS, LFMI-10 Center Drive Bldg. 10, Rm. B1D108, MSC 1065 Bethesda, MD 20892-1065 Phone: (301)402-0389 FAX: (301)480-2558 Email: doddst at ninds.nih.gov
|
|
Back to People/Contact Page Recent Publications
Recent Publications in LFMI
| Top |
- J. Tucciarone, K. Chuang, S.J. Dodd, A.C. Silva, G. Pelled, A.P. KoretskyLayer specific tracing of corticocortical and thalamocortical connectivity in the rodent using manganese enhanced MRI, NeuroImage 44: 923-931(2009)
Link to PubMed
- A.G. Goloshevsky, A.C. Silva, S.J. Dodd, A.P. KoretskyBOLD fMRI and somatosensory evoked potentials are well correlated over a broad range of frequency content of somatosensory stimulation of the rat forepaw, Brain Research 1195: 67-76(2008)
Link to PubMed
- G. Zabow, S.J. Dodd, J. Moreland, A.P. KoretskyMicro-engineered local field control for high-sensitivity multispectral MRI, Nature Neuroscience 453: 1058-1063(2008)
Link to PubMed
- G. Goelman, G. Pelled, S.J. Dodd, A.P. KoretskyTracking the effects of crusher gradients on gradient-echo BOLD signal in space and time during rat sensory stimulation, Magnetic Resonance in Medicine 60: 548-554(2008)
Link to PubMed
- G. Pelled, K. Chuang, S.J. Dodd, A.P. KoretskyFunctional MRI Detection of Bilateral Cortical Reorganization in the Rodent Brain Following Peripheral Nerve Deafferentation, NeuroImage 37: 262-273(2007)
Link to PubMed
- G. Goelman, G. Pelled, S.J. Dodd, A.P. KoretskyObservation of two distinct spatial-temporal BOLD clusters during sensory stimulation in rats, NeuroImage 34: 1220-1226(2007)
Link to PubMed
- G. Pelled, S.J. Dodd, A.P. KoretskyCatheter confocal fluorescence imaging and functional magnetic resonance imaging of local and systems level recovery in the regenerating rodent sciatic nerve, NeuroImage 30: 847-856(2006)
Abstract PDF Full Text
- G. Goelman, G. Pelled, S.J. Dodd, A.P. KoretskyObservation of two distinct spatial-temporal BOLD clusters during sensory stimulation in rats., NeuroImage : -(2006)
- B. Ozus, G. Clarke, S.J. Dodd, G. FullertonOrientational dependence of intermolecular double quantum coherence (iDQC) signal from tendon tissue, Magnetic Resonance in Medicine 53: 1183-1186(2005)
- T. Andrews, J. Lancaster, S.J. Dodd, C. Contreras-sesvold, P. FoxTesting the three-pool white matter model adapted for use with T2 relaxometry, Magnetic Resonance in Medicine 54: 449-454(2005)
- L. Krasnosselskaia, G. Fullerton, S.J. Dodd, I. CameronWater in tendon: orientational analysis of the free induction decay, Magnetic Resonance in Medicine 54: 280-288(2005)
- S. Maswadi, S.J. Dodd, J. Gao, R. GlickmanTemperature mapping of laser-induced hyperthermia in an ocular phantom using magnetic resonance thermography, Journal of Biomedical Optics 9: 711-718(2004)
- J. Lancaster, T. Andrews, L. Hardies, S.J. Dodd, P. FoxThree-pool model of white matter, Journal of Magnetic Resonance Imaging 17: 1-10(2003)
- S.J. Dodd, D.S. Williams, C. Olsen, A.C. Silva, A.P. Koretsky, C. HoAn open transverse z-gradient coil designs for magnetic resonance imaging, Rev. Sci. Instru. 73: 2208-2210(2002)
- S.J. Dodd, C. HoShort planar gradient coils for MR microscopy using concentric return paths, Journal of Magnetic Resonance Series A 156: 1-9(2002)
- S. Kanno, Y.L. Wu, P.C. Lee, S.J. Dodd, M. Williams, B.P. Griffith, C. HoMacrophage accumulation associated with rat cardiac allograft rejection detected by magnetic resonance imaging with ultrasmall superparamagnetic iron oxide particles, Circulation 104: 934-938(2001)
- S. Kanno, P.C. Lee, S.J. Dodd, M. Williams, B.P. Griffith, C. HoA novel approach with magnetic resonance imaging used for the detection of lung allograft rejection, Journal of Thorac Cardiovasc Surg. 58: 1300-1310(2000)
- Y. Zhang, S.J. Dodd, K. Hendrich, M. Williams, C. HoMagnetic resonance imaging detection of rat renal transplant rejection by monitoring macrophage infiltration, Kidney Int. 58: 1300-1310(2000)
- S. Yoshida, S.J. Dodd, P. Del nido, D.S. Williams, C. HoCardiac function of transplanted rat hearts using a working heart model assessed by magnetic resonance imaging, Journal of Heart Lung Transplant 18: 1054-1064(1999)
- S.J. Dodd, M. Williams, J. Suhan, D.S. Williams, A.P. Koretsky, C. HoDetection of single mammalian cells by high-resolution magnetic resonance imaging, Biophys J. 76: 103-109(1999)
- S. Crozier, S.J. Dodd, D. DoddrellA novel design methodology for Nth order, shielded longitudinal coils for NMR, Meas. Sci. Technol. 7: 36-41(1996)
- F. Zelaya, S.J. Dodd, R. Mckenna, D. DoddrellMeasurement and compensation of field inhomogeneities caused by differences in magnetic susceptibility, Journal of Magnetic Resonance Series A 115: 131-136(1995)
- S. Crozier, S.J. Dodd, D. DoddrellThe design of biaplanar, shielded, minimum energy, or minimum power pulsed B0 coils, MAGMA 3: 49-55(1995)
- S. Crozier, S.J. Dodd, D. DoddrellDesign of shielded quadrupolar gradient coils for magnetic resonance microscopy by simulated annealing, IEEE Trans Magn. 30: 1242-1246(1994)
|